RF 전도 내성 시험 시스템
사용자 설명서
적용 할 수있는 LISUN models: AB-EM
The AB-EM electromagnetic clamp complies with the national standard IEC 61000-4-6 and is a specialized product for testing the immunity of equipment to radio-frequency field-induced conducted disturbances.injecting disturbance signals into the cable assemblies in the slots so that the Equipment Under Test (EUT) is subjected to the levels specified in the national standard.
For precise measurements, the electromagnetic clamp is also equipped with an auxiliary absorption clamp and calibration pieces.
기능
See Tables 1 and 2 for the coupling coefficient and attenuation characteristic curves; the difference is 9.5 dB ± 1.5 dB.
Maximum input power: 100 W (5 minutes);
Injection frequency: 150 kHz to 230 MHz;
At frequencies greater than 10 MHz, the coupling/decoupling directivity is greater than 10 dB
Measurable cable diameter: <Φ18 mm
첨부 파일
Instruction Manual 1 copy
Test Cable One
100W 6dB Attenuator One
Calibration Fixture (Optional) One set
Using Connection Diagrams
AB-EM

AB-EM Data Sheet
Serial No.: 21021 Differential Error: 9.5 dB ± 1.5 dB Date: April 29, 2021
| 주파수 (MHz) | Coupling Coefficient (dB) | Attenuation Coefficient (dB) | Difference (dB) |
| 0.15 | -2.7 | -12.3 | 9.6 |
| 0.2 | -2.4 | -12.0 | 9.6 |
| 0.3 | -2.2 | -11.8 | 9.6 |
| 0.32 | -2.2 | -11.8 | 9.6 |
| 0.35 | -2.2 | -11.8 | 9.6 |
| 0.4 | -2.1 | -11.8 | 9.7 |
| 0.45 | -2.1 | -11.8 | 9.7 |
| 0.5 | -2.1 | -11.8 | 9.7 |
| 0.55 | -2.1 | -11.8 | 9.7 |
| 0.6 | -2.1 | -11.8 | 9.7 |
| 0.65 | -2.1 | -11.8 | 9.7 |
| 0.74 | -2.1 | -11.8 | 9.7 |
| 0.75 | -2.1 | -11.8 | 9.7 |
| 0.8 | -2.2 | -11.9 | 9.7 |
| 0.85 | -2.3 | -11.9 | 9.6 |
| 0.9 | -2.4 | -12.1 | 9.7 |
| 0.95 | -2.5 | -12.1 | 9.6 |
| 1 | -2.5 | -12.1 | 9.6 |
| 1.5 | -2.1 | -11.7 | 9.6 |
| 2 | -2.1 | -11.7 | 9.6 |
| 2.5 | -2.1 | -11.7 | 9.6 |
| 3 | -2.1 | -11.7 | 9.6 |
| 4 | -2.2 | -11.8 | 9.6 |
| 5 | -2.2 | -11.8 | 9.6 |
| 6 | -2.3 | -11.8 | 9.5 |
| 7 | -2.4 | -11.8 | 9.4 |
| 8 | -2.4 | -11.8 | 9.4 |
| 9 | -2.5 | -11.9 | 9.4 |
| 10 | -2.6 | -11.9 | 9.3 |
| 12 | -2.8 | -12.1 | 9.3 |
| 15 | -3.2 | -12.4 | 9.2 |
| 18 | -3.5 | -12.6 | 9.1 |
| 20 | -3.6 | -12.8 | 9.2 |
| 22 | -3.6 | -12.8 | 9.2 |
| 25 | -3.5 | -12.8 | 9.3 |
| 28 | -3.1 | -12.4 | 9.3 |
| 30 | -2.6 | -11.9 | 9.3 |
| 32 | -2.2 | -11.5 | 9.3 |
| 35 | -1.3 | -10.6 | 9.3 |
| 38 | -0.5 | -9.8 | 9.3 |
| 40 | 0.0 | -9.3 | 9.3 |
| 45 | 1.1 | -8.4 | 9.5 |
| 50 | 1.8 | -7.8 | 9.6 |
| 60 | 2.5 | -7.4 | 9.9 |
| 70 | 2.6 | -7.1 | 9.7 |
| 80 | 2.7 | -6.9 | 9.6 |
| 85 | 2.9 | -6.9 | 9.8 |
| 90 | 3.0 | -6.9 | 9.9 |
| 95 | 3.2 | -6.9 | 10.1 |
| 100 | 3.3 | -6.8 | 10.1 |
| 120 | 3.5 | -6.8 | 10.3 |
| 140 | 3.4 | -7.0 | 10.4 |
| 160 | 2.6 | -8.0 | 10.6 |
| 180 | 1.9 | -8.2 | 10.1 |
| 200 | 0.9 | -9.3 | 10.2 |
| 210 | 0.6 | -9.6 | 10.2 |
| 220 | 0.1 | -10.1 | 10.2 |
| 230 | -0.1 | -10.3 | 10.2 |


List of AB-EM Calibration Fixtures
| 그렇지 않습니다. | 모델 | 이름 | Quantity/piece |
| 1 | M-004 | 150Ω/50Ω Adapter | 2 |
| 2 | M-006 | 5 W / 50 Ω load | 1 |
| 3 | E-001 | L-Shaped Calibration Bracket | 2 |
| 4 | E-003 | 4mm Test Rod (725mm) | 1 |
*The 4mm test probe is inside the electromagnetic clamp packaging box;
LED Luminaires and LED Power Driver Test Solution
고니오포토미터 시스템: LSG-6000, LSG-1890B및 LSG-1700
분광복사계 및 적분구 테스트 시스템: LPCE-2 or LPCE-3
LED Life Maintains a Test System in Accordance with LM-80: LEDLM-80PL
Waterproof Test for IPX5 and IPX6 Levels: JL-56
Dustproof Testing Machine for IP5X and IP6X Testing: SC-015
LED 전원 드라이버 테스터: LS2090 (for the lab) and ATE-2 (for the production line)
Electrical Safety Tester: LS9955
CFL and Electronic Ballast Test Solution
고니오포토미터 시스템: LSG-1890B or LSG-1700
Integrating Sphere and Spectrophotometer Test System: LPCE-2 or LPCE-3
Adjustable Reference Ballast: DYJ-50HZ, HCS-109A예산 및 DYJ-HID
Electric Ballast Tester: WT5000 (for the lab) and ATE-1 (for the production line)
Digital Torsion Meter and Multiway Life Tester: CH338 CH316
전기 안전 검사원: LS9923, ZRS-3H, ZY-3
CFL 및 LED 조명기구용 EMC 및 EMI 테스트 솔루션
EMI 테스트 시스템: EMI-9KB or EMI-9KA
정전기 방전 시뮬레이터: ESD61000-2
EFT 면역력 측정: EFT61000-4
서지 생성기: SG61000-5
전압 강하 및 정전 발생기: CSS61000-11
링 웨이브 발생기: RWG61000-12

WWW. Lisun그룹닷컴
특허 출원
모든 권리는 다음에 의해 보호됩니다. Lisun 그룹
사전 고지 없이 변경될 수 있습니다.

中文简体